bareos_power_on_off_sd [2017/02/18 19:02] herwarthbareos_power_on_off_sd [2017/02/18 19:09] (current) herwarth
Line 6: Line 6:
 The server is a Supermicro machine with IPMI, so I am using ipmiutils to power on/off the machine. The server is a Supermicro machine with IPMI, so I am using ipmiutils to power on/off the machine.
  
-=====Philosophy===== +=====Powering off the SD===== 
-The catalog backup runs with a lower priority so shutting down the server after the catalog backup makes sense. In a schedule I always end with creating a catalog backup +The catalog backup runs with a lower priority so shutting down the server after the catalog backup makes sense. In a schedule I always end with creating a catalog backup. When the SD is powered down, I do not want to power it down again.
  
 =====Catalog backup===== =====Catalog backup=====
Line 120: Line 120:
 done done
 </code> </code>
 +=====Powering on the SD when running a job=====
 +When I need to write a backup to the bareos-sd server, I need to power it on. But I do not want to power it on when it is already on. It is possible a job will be triggered with another job still running.
 +<code - /etc/bareos/bareos-dir.d/job/example.conf>
 +Job {
 +  .
 +  .
 +  .
 +  RunBeforeJob = /usr/lib/bareos/scripts/poweron_bareos_sd.sh
 +}
 +</code>
 +<code - /usr/lib/bareos/scripts/poweron_bareos_sd.sh>
 +#!/bin/bash
 +BAREOS_SD_IP=172.16.2.23
 +BAREOS_SD_PORT=9103
 +IPMI_IP=172.16.2.18
 +IPMI_USER=USER
 +IPMI_PASS=PASSWORD
 +SLEEP=5
 +NUM_TRIES=24
  
 +function check_bareos_sd {
 +  nc -w1 $BAREOS_SD_IP $BAREOS_SD_PORT < /dev/null 2>/dev/null
 +  if [ $? -eq 0 ]; then
 +  # if return value is 0 then port is reachable so we can exit the function with value 0
 +    return 0
 +  else
 +    return 1
 +  fi
 +}
  
 +COUNT=0 
 +while true; do 
 +  check_bareos_sd 
 +  if [ $? -eq 0 ]; then 
 +    # We are online, so exit loop 
 +    exit 0 
 +  else 
 +    # We are offline, so add 1 to counter, sleep for $SLEEP seconds and continue loop 
 +    # $COUNT=0 then we can power on the machine using ireset (ipmiutil) 
 +    if [ $COUNT -eq 0 ]; then 
 +      ireset -u -N $IPMI_IP -U $IPMI_USER -P $IPMI_PASS >/dev/null 2>&
 +    fi 
 +    let COUNT=$COUNT+1 
 +    sleep $SLEEP 
 +  fi 
 +  # check if $COUNT reaches $NUM_TRIES and when it does exit with value 1 
 +  if [ $COUNT -eq $NUM_TRIES ]; then 
 +    exit 1 
 +  fi 
 +done 