This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| vmware_nmp_iops [2015/05/25 12:40] – herwarth | vmware_nmp_iops [2016/12/31 16:20] (current) – herwarth | ||
|---|---|---|---|
| Line 72: | Line 72: | ||
| Set the new IOPS value using the following command: | Set the new IOPS value using the following command: | ||
| esxcli storage nmp psp roundrobin deviceconfig set -d t10.FreeBSD_iSCSI_Disk______001517bc5bf6001_________________ -t iops -I 1 | esxcli storage nmp psp roundrobin deviceconfig set -d t10.FreeBSD_iSCSI_Disk______001517bc5bf6001_________________ -t iops -I 1 | ||
| - | In this case it is value 1. I have bench-marked 4 values( 1000 (default), 100, 10 and 1) | + | In this case it is value 1. I have bench-marked 4 values (1000 (default), 100, 10 and 1) |
| + | |||
| + | =====SATP rule==== | ||
| + | To make it last a reboot: | ||
| + | esxcli storage nmp satp rule add -s " | ||
| =====Results===== | =====Results===== | ||
| Line 89: | Line 93: | ||
| storage path2 (iscsi2 VLAN) | storage path2 (iscsi2 VLAN) | ||
| {{ : | {{ : | ||
| + | |||
| + | =====Results jumbo frames===== | ||
| + | |||
| + | {{: | ||
| =====Conclusion==== | =====Conclusion==== | ||